Before installing or using your solar air conditioner, please print and read this manual carefully
and keep it for future reference.
Please read this installation manual completely before installing the product. If the power cord is damaged,
replacement must be performed by authorized personnel only. Installation work must be performed in accordance
with the NEC and local codes. You should contact a licensed service technician for installation, repair, or maintenance.
Improper installation could damage the system and/or void the warranty and could result in injury, death, or property
damage.
.
Notice To Owner/Installer:
This unit is designed for easy installation by an experienced person. It is legal for a
homeowner to install it, however we highly recommend using a licensed HVAC
technician for installation.
Legal Information About Self-Installing R410A Air Conditioners
Can a homeowner install this system?
Yes, a homeowner with a vacuum pump, proper training, and equipment can install this unit. Unless
you are experienced with installing air conditioners we recommend you hire a professional installer. The
person who installs the system must do all work in compliance with local building and electrical codes.
Are there any restrictions on the purchase of R410A refrigerants?
R410a is not an ozone-depleting substance. At this time the purchase of R410a refrigerant is not restricted
in the US. There is no technician certification requirement for those that purchase HFC refrigerants, such as
R-410a or R-134a. If you are not licensed, some local HVAC supply companies may refuse to sell you
R410a based on a misunderstanding of the law, or because they wish to discourage homeowners from
working on their own systems.
Are there any restrictions on the use of R410A refrigerants?
Yes, it is illegal to knowingly vent or release these refrigerants. The venting prohibition applies to R410a,
and all other HFC refrigerants, just as it does for ozone-depleting refrigerants like R-22.
Is EPA technician certification required to service R410A systems?
No, at this time EPA technician certification is not required in order to service R-410a systems.
Source: http://www.epa.gov/ozone/title6/phaseout/technicians_contractors_faq.html
ACDC12 Solar Air Conditioner
Heat Pump
Model ACDC12 Solar Heating & Cooling Heat Pump Mini-Split System
Installation Manual
Page view 0
1 2 3 4 5 6 ... 29 30

Summary of Contents

Page 1

Before installing or using your solar air conditioner, please print and read this manual carefully and keep it for future reference. Please rea

Page 2 - CONTENTS

ELECTRICAL WORK C: Putting Nut On Remove flare nuts attached to indoor and outdoor unit, then put them on pipe/tube having completed burr removal.

Page 3 - SAFETY PRECAUTIONS

ELECTRICAL WORK Minimum nominal cross-sectional area of conductors: Rated current Nominal cross-sectional of appliance area (A) (mm) NOTE:

Page 4 - INSTALLATION INSTRUCTIONS

ELECTRICAL WORK 7. Reinstall the electrical box cover, keep the white band just under the groove as shown in Fig. 26a and curve the cable into the g

Page 5

ELECTRICAL WORK Installation of the solar photovoltaic system This guide contains information regarding the installation and safe handling of solar

Page 6

ELECTRICAL WORK When disconnecting wires from a photovoltaic module that is exposed to sunlight, an electric arc may result. Such arcs may cause bur

Page 7 - INSTALLATION INSTRUCTIONS

Do NOT Connect in Series. It must be a Parallel connection.

Page 8

ELECTRICAL WORK Only perform installation in dry conditions. Fig.38 Abide with the safety regulations for all other components used in the system, i

Page 9 - 1. Flaring work

ELECTRICAL WORK Fig.40 2. Selecting the proper support frame Always observe the instructions and safety precautions included with the support frame

Page 10 - ELECTRICAL WORK

4. Roof mount ELECTRICAL WORK When installing a module on a roof or building, ensure that it is securely fastened and cannot fall as a result of wi

Page 11

ELECTRICAL WORK 6. General installation Module mounting must use the pre-drilled mounting holes in the frame. The most common mounting is achieved

Page 12

CONTENTS SAFETY PRECAUTIONS Warning 2 Caution 2 Selecting installation location 3 Accessories 4 Indo

Page 13

Extension cables will be needed in the 3 panel configuration connecting The J-Box cables to the combiner box. See figure 52a.

Page 14

ELECTRICAL WORK Connection method B: Using 2 panels see Fig.52b. Outdoor unit wire connection Fig.52b If you want to connect the photovoltaic mo

Page 16

GROUNDING PRINCIPALS • Equipment grounding provides protection from shock caused by a ground fault and is required for all PV systems by the NEC.

Page 17

2 Panel Grounding 23 Liquid Tight conduit may be used between the Standard AC Disconnect and the 30 AMP internal breaker in the Outdoor Unit. Max 6 f

Page 18

3 Panel Grounding 24 Liquid Tight conduit may be used between the Standard AC Disconnect and the 30 AMP internal breaker in the Outdoor Unit. Max 6 f

Page 19

ELECTRICAL WORK Do not attach the cable on the sharp edge of the frames. Fig.54 Attention to the minimum bending radius of the wire. Fig.55 Do no

Page 20

ELECTRICAL WORK If you want to use the connector purchased by yourself, the following requirements must be complied: Use only connector special des

Page 21

EVACUATION CAUTION After complying to the above conditions, prepare the wiring as follows: 1) Never fail to have an individual power circuit specifi

Page 22 - Wiring the MNPV3

EVACUATION When moving the unit to new location, perform evacuation using vacuum pump. Make sure the refrigerant added into the air conditioner is

Page 23 - GROUNDING PRINCIPALS

SAFETY PRECAUTIONS Read the follow SAFETY PRECAUTIONS carefully before installation. Electrical work must be installed by a licensed electrician. Be

Page 25 - 3 Panel Grounding

INSTALLATION INSTRUCTIONS Selecting installation location Select an installation location which is rigid and strong enough to support or hold the un

Page 27 - Disclaimer of liability

INSTALLATION INSTRUCTIONS Indoor unit installation 1. Fit the installation plate horizontally on structural parts of the wall with spaces around

Page 28 - EVACUATION

INSTALLATION INSTRUCTIONS Connective Tube and Drainage Installation 1. Run the drain hose sloping downward. Do not install the drain hose as i

Page 29 - Liquid side D

INSTALLATION INSTRUCTIONS Piping and wrapping Bundle the tubing, connecting cable, and drain hose with tape securely, evenly as shown in Fig.11 B

Page 30

REFRIGERANT TUBE CONNECTION Placement of outdoor unit Anchor the outdoor unit with bolts and nuts on a concrete or rigid mount. . Drain Joint Ins